Rated current In (A): 80A, 100A, 125A

Rated voltage Ue (V): DC60/80V, AC230/240/400/415V

Poles: 1P, 2P, 3P, 4P

Breaking capacity (Icu): 4.5kA, 10kA

Certifications: CCC, CB, CE, TUV

Technical parameters:

Rated Voltage (Ue)DC60/80V(1P), AC230/240V(1P ,2P), AC400/415V(3P,4P)
Rated Current (In)80A, 100A, 125A
Tripping Characteristic/
Tripping curveType C
Rated Breaking Capacity (Icn)/
Rated Ultimate Short-Circuit Breaking Capacity (Icu)AC Icu :4.5kA , DC Icu :10kA
Rated Service Short-Circuit Breaking Capacity (Ics)AC Ics: 4.5kA , DC Ics :10kA
Number of Poles1P, 2P, 3P, 4P
Standards and Certificates·CCC, CB, CE, TUV ·GB/T14048.2、IEC 60947-2
Environmental RequirementsRoHS
Rated Insulation Voltage500V
Rated Impulse Withstand Voltage4kV
Rated Frequency50/60Hz
Wiring·Adopt tunnel type wiring ·Connection capability: 1mm² to 50 mm² ·Connection screw M6, Torque: 3.0N.m
Mechanical Life8500 times
Electrical Life1500 times
Working Condition·Ambient temperature: -25℃~+75℃ ·Storage temperature: -40℃~+80℃ ·Relative air humidity ≤95% ·Resistance to heat and humidity: in case of ambient temperature 55℃ ·Altitude ≤2000m. In case of use at higher altitude, it may be derated according to the requirements of small-sized circuit breaker of the company. Refer to GB/T 20645 Specific Environmental Condition Technical Requirements of Low-voltage Apparatuses for Plateau. ·Pollution degree: 3 ·Protection Degree: IP20 ·Protection grade for device which is installed in distribution box: IP40 ·Working site without obvious vibration and shock
Isolation function·Practical breaking instructions ·View window within the green identification said contact in the off position

Packing and depositing:

·Quantity(1P product:12PCS/box,1PN/2P product:6PCS/box,3P product:4 PCS/box,3PN/4P product: 3PCS/box)

·Packing boxes of products should be stored in the air circulation and relative humidity is not more than 95% and the temperature is not higher than + 75 ℃,not less than - 25 ℃ in the air around without acid, alkali or other corrosive gases stored in the warehouse. In the above conditions, the storage period since the production date not more than three years.


Quality Controls

Delivery Guarantees

Made in China

Made in China

Transaction Visualization

No Worries After-sales

Professional Experience