NDB1-63 Series AC/DC MCB, Nader

Rated current In (A): 1A, 2A, 3A, 4A, 5A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Rated voltage Ue (V): AC230/240/400/415V, DC60/80V

Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P

Breaking capacity (Icu): 6kA, 10kA

Certifications: CCC, CB, CE, TUV

Technical parameters:

Rated Voltage (Ue)

AC230/400V (1P), AC240/415V (1P), AC230/240 (1P+N), AC400/415 (2P、3P、3P+N、4P), DC60/80 (1P、2P)

Rated Current (In)

1A, 2A, 3A, 4A, 5A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Tripping Characteristic

B:3In~5In, C:5In~10In, D:10In~14In

Tripping curves

B type curve, C type curve, D type curve

Rated Breaking Capacity (Icn)

6kA:AC230/240/400/415V, 10kA:DC60/80V

Rated Ultimate Short-Circuit Breaking Capacity (Icu)

6kA:AC230/240/400/415V, 10kA:DC60/80V

Rated Service Short-Circuit Breaking Capacity (Ics)

6kA:AC230/240/400/415V, 7.5kA:DC60/80V

Number of Poles

1P、1PN、2P、3P、3PN、4P

Standards and Certificates

·CCC, CB, CE, TUV

·GB/T10963.1 、IEC 60898-1

Environmental Requirements

RoHS

Rated Insulation Voltage

500V

Rated Impulse Withstand Voltage

4kV

Rated Frequency

50/60Hz

Wiring

·Adopt tunnel type wiring Version

·Connection capability: 1mm² to 25 mm²

·Connection screw M5, Torque: 2N.m

·Lines in for both up and down ends

Mechanical Life

20000 times

Electrical life

10000 times

Working Condition

·Ambient temperature:-40℃~+70℃

·Stored ambient temperature:-40℃~+80℃

·Heat and humidity resistance:The relative air humidity ≤95% at the temperature of+55℃

· Altitude:≤2000m, if you want to apply it more than 2000m, you must refer to Miniature Circuit Breaker’s reduced capacity table. Also you can refer to GB/T20645 the technological requirement of the low-voltage electrical equipment when it is used on high altitude.

·Pollution degree: 3

·Protection Degree: IP20

Isolation function

·Practical breaking instructions

·View window within the green identification said contact in the off position

Use Category

A

Mounting Class

II、III

Tripping characteristic curve

Outline and installation dimension

Packing and depositing:

·Quantity(1P product:12PCS/box,1PN/2P product:6PCS/box,3P product:4 PCS/box,3PN/4P product: 3PCS/box)

·Packing boxes of products should be stored in the air circulation and relative humidity is not more than 80% and the temperature is not higher than + 80 ℃, not less than- 40 ℃ in the air around without acid, alkali or other corrosive gases stored in the warehouse. In the above conditions, the storage period since the production date not more than three years.

Quality Controls

Delivery Guarantees

Made in China

Made in China

Transaction Visualization

No Worries After-sales

Professional Experience