NDM3Z-630V Series DC MCCB, Nader

Rated current In (A): 400A, 450A, 500A, 630A

Rated voltage Ue (V): DC1500V

Poles: 2P

Rated ultimate short-circuit breaking capacity Icu (kA): 15kA, 20kA

Certifications: CCC, CB, CE, TUV

Technical parameters:

Rated current of frame Inm (A)

630A

Rated Current (In) (A)

400A, 450A, 500A, 630A

Rated Insulation Voltage Ui (V)

1600V

Rated impulse withstand voltage Uimp (V)

12000V

Tripping Characteristics

/

Rated limit short-circuit breaking capacity level

/

Number of Poles

2P

Rated Voltage (Ue) (V)

DC1500V

Rated limit short-circuit breaking capacity Icu (kA)

20kA (τ=5ms)/15(τ=10ms)

Rated operating short-circuit breaking capacity Ics (kA)

20kA (τ=5ms)/15(τ=10ms)

Rated Frequency (Hz)

50/60Hz

Standards and Certificates

·CCC, TUV, CE

·GB/T 14048.1, GB/T 14048.2, IEC 60947-1, IEC 60947-2

Maintenance-free life

7000 times

Maintainable life

14000 times

Electrical Life

1000 times

Flashover distance(mm)

65mm (With terminal cover), 150mm (Without terminal cover)

Wiring mode

Front-Panel

Thread diameter

M10 (Torque value: 20N.m), M5 (Torque value: 4N.m)

Connection capacity

240mm² (400A), 150mm² (450A, 500A), 185mm² (630A)

Normal Working Environment

·Ambient Temperature: -35℃~+70℃

·Storage Temperature: -40℃~+75℃

·Altitude: ≤2500m

·Environmental Requirements: RoHS

·Relative Humidity: The relative humidity at an ambient temperature of +40℃ should not exceed 50%. A higher relative humidity is allowed at a lower temperature.

·The product can withstand the effects of wet air, salt mist and oil mist.

·Pollution Level: 3

·Protection class: IP20

Isolation Function

·Installation Category:

The installation category of the circuit breaker connected to the main loop is:Ⅲ(power distribution and control level);

The installation category of the circuit breaker not connected to the main loop is:Ⅱ(load level).

·Installation Environment:

The product should be installed in places that are free from explosive media, media corrosive to metal, insulation damaging gas, and conductive dust, which should be also avoided from snow and rain.

Tripping characteristic curve

Outline and installation dimension

Packing and depositing:

·Minimum packaging quantity: 1 piece/box.

·The packaged products should be stored in a warehouse with the ambient temperature of-40℃~75 ℃ and the corresponding relative humidity below 80% without acidic, alkali or other corrosive gas in the surrounding air. Under the conditions above, the storage period shall be no more than 36 months since the manufacturing date.

Quality Controls

Delivery Guarantees

Made in China

Made in China

Transaction Visualization

No Worries After-sales

Professional Experience