Poles: 3P
Agreed Free-air Thermal Current (Ith): 1450A
Utilization Category: AC-1, AC-3
Rated Operational Current (Ie): AC-1:1080/1184/1450A; AC-3:1000A
Rated Operational Voltage (Ue): AC380/400V/415V, AC660/690V, AC1000V, AC1140V
Coil Voltage (Uc): AC/DC: 48–110V, 110–250V, 250–500V
Certifications: CCC, CB, CE, TUV
NDC5K-1450R AC contactor is mainly used in the photovoltaic and wind power industry, for remote connecting and breaking of the circuit. The contactor can also be used in the industrial control sector for remote connecting &breaking, and frequently starting &controlling AC motors, which can control the inverse operation or reverse brake of the AC motors.
| Specification | NDC5K630 | NDC5K-630H | NDC5K-800 | NDC5K-80H | NDC5K-1450R | NDC5K-1450R/H | NDC5K-1700R | NDC5K-1700R/H | |||
| Poles | 3 | 3 | 3 | 3 | |||||||
| Conventional free-air thermal current Ith (A) | 1050 | 1310 | 1450 | 1720 | |||||||
| Rated current (A) | AC-1Ue≤114DV | 0≤40℃ | 1050 | 1310 | 1450 | 1720 | |||||
| 0≤50℃ | 931 | 1250 | 1450 | 1720 | |||||||
| 0≤55℃ | 888 | 1155 | 1450 | 1720 | |||||||
| 0≤65℃ | 850 | 1100 | 1184 | 1450 | |||||||
| 0≤70℃ | 700 | 900 | 1080 | 1350 | |||||||
| AC-3 | 380/400V | 630 | 800 | 1000 | 1250 | ||||||
| 660/690V | 630 | 800 | 1000 | 1250 | |||||||
| 1000V | 420 | 580 | / | / | |||||||
| AC-4 | 380/400V | 510 | 650 | ||||||||
| 660/690V | 510 | 650 | |||||||||
| 1000V | 345 | 465 | |||||||||
| Rated power (kW) | AC-1+40℃ | 380/400V | 650 | 766 | 914 | 1071 | |||||
| 660/690V | 1130 | 1330 | 1576 | 1861 | |||||||
| 1000V/1140V | 1712 | 2015 | 2044 | 2417 | |||||||
| AC-3 | 380/400V | 355 | 450 | / | / | ||||||
| 660/690V | 630 | 750 | |||||||||
| 1000V | 600 | 800 | |||||||||
| AC-4 | 380/400V | 280 | 355 | ||||||||
| 660/690V | 494 | 633 | |||||||||
| 1000V | 509 | 678 | |||||||||
| Average power loss per pole (W) | at Ith | 69 | 96 | 135 | 188 | ||||||
| Rated operational voltage (V) | AC380/400V/415V,AC660/690V,AC1000V,AC1140V | ||||||||||
| Insulation voltage Ui | AC1250V | ||||||||||
| Impulse withstand voltage Uimp | 12kV | ||||||||||
| Rated limiting short-circuit current for type “2” coordination | Test current | 50kA | 50kA | 50kA | 50kA | ||||||
| Rated control voltage Uc | AC/DC;48V-110V,110V-250,250V-500V | ||||||||||
| Control voltage range | Pick-up: 0.7×Ucmin–1.15×Ucmax | ||||||||||
| (with control transformer impedance voltage ≤0.7) | Drop-out: 0.2–0.6 Ucmin | ||||||||||
| Control circuit overvoltage protection | In hold state, when control voltage Uc>1.3 Ucmax the device releases to protect the internal circuit | ||||||||||
| Cold state, power consumption at 1.0×Uc (with control transformer impedance voltage ≤0.7) | Pick-up | AC VA / DC W | 900 (standard type), 1170 (plateau type) | ||||||||
| Hold | AC | 45 VA (apparent), 20 W (active) | |||||||||
| DC | 15 W (standard type), 18 W (plateau type) | ||||||||||
| Specification | NDC5K-630 | NDC5K-630H | NDC5K-800 | NDC5K-800H | NDC5K-1450R | NDC5K-1450RH | NDC5K-1700R | NDC5K-1700R/H | |||
| Operating time | A1-A2 control | From A1-A2 energized to main contacts closing: 30–120 ms | |||||||||
| From A1-A2 de-energized to main contacts opening: 33–70 ms | |||||||||||
| PLC control (DC 24 V) | PLC signal input to main contacts closing: 30–90 ms | ||||||||||
| PLC signal input to main contacts opening: 10–40 ms | |||||||||||
| Rated making capacity at 690 V (A) | 7800 | 9840 | 9840 | 9840 | |||||||
| Rated breaking capacity (A) | 400V | 6500 | 8200 | 8200 | 8200 | ||||||
| 690V | 6500 | 8200 | 8200 | 8200 | |||||||
| 1000V | 4350 | 5800 | 5800 | 5800 | |||||||
| 1140V | 1575 | 1965 | 2175 | 2580 | |||||||
| Mechanical life at Uc (×10⁴ operations) | 300 | ||||||||||
| Operating frequency | 600 operations/h | ||||||||||
| Electrical life (×10⁴ operations) | AC-1 | 400V | 65 | 100 | 53 | 80 | 40 | 60 | 30 | 50 | |
| Frequency (operations/h) | 600 | 300 | |||||||||
| 690V | 30 | 50 | 26 | 40 | 18 | 28 | 13 | 20 | |||
| Frequency (operations/h) | 200 | 150 | |||||||||
| AC-3 | 400V | 65 | 100 | 65 | 100 | ||||||
| Frequency (operations/h) | 500 | / | |||||||||
| AC-4 | 400V | 10 | 15 | 4 | 6 | ||||||
| Frequency (operations/h) | 200 | ||||||||||
| Short-time withstand current (from cold state, 0≤40 °C, no current during the previous 60 min) | 1s | 8000A | 10000A | ||||||||
| 10s | 7200A | 8000A | |||||||||
| 30s | 5200A | 5200A | |||||||||
| 1min | 4000A | 4000A | |||||||||
| 3min | 2500A | 3000A | |||||||||
| 10min | 1700A | 2000A | |||||||||
| 15min | 1500A | 1800A | |||||||||
| Main circuit wiring capacity (for multiple busbars, upper and lower clamping required) | Cable with ferrules (mm²) | min 50,max 240 | min 50,max 240 | / | |||||||
| Busbar width (mm) | 50 | 60 | 70 | 80 | |||||||
| Single busbar thickness (mm) | 5 | 5 | 5 | 5 | |||||||
| Main circuit connection bolts | M12 | M12 | M12 | M12 | |||||||
| Tightening torque (N·m) | 35±5 | 35±5 | 35±5 | 35±5 | |||||||
| Weight (kg) | 16 | 16 | 18 | 18 | |||||||
| Product certification | CCC,CE,TUV | ||||||||||
| Product standard | GB/T 14048.4,IEC 60947-4-1 | ||||||||||
| Auxiliary contact parameters | |||||||||||
| Auxiliary contacts comply with GB/T 140485, IEC 60947-5-1 | Each contactor has one NO and one NC auxiliary contact; these contacts are mechanically connected together by the same movable contact carrier | ||||||||||
| Mirror contacts comply with GB/T 140484, IEC 60947-4-1 | The NC contact on each contactor is in mirror position to the state of the main contacts | ||||||||||
| Model | F1-11L/C5K-800 | F1-11LS/C5K-800 | |||||||||
| Rated insulation voltage | 690V | 250V | |||||||||
| Impulse withstand voltage | 6kV | 2.5kV | |||||||||
| Conventional free-air thermal current Ith | 16A | 0.1A | |||||||||
| Utilization category | AC-15 DC-13 | AC-14 DC-12 | |||||||||
| Specification | NDC5K-630 | NDC5K-630H | NDC5K-800 | NDC5K-800H | NDC5K-1450R | NDC5K-1450RH | NDC5K-1700R | NDC5K-1700RH | |||
| Rated operational voltage/current | AC-15 | 230V 50/60Hz 6A | AC-14 | 125V 50/6DHz 0.1A | |||||||
| 400V 50/60Hz 4A | / | ||||||||||
| 500V 50/60Hz 1.5A | / | ||||||||||
| DC-13 | DC24V 6A | DC-12 | DC30V 01A | ||||||||
| DC48V 2.8A | / | ||||||||||
| DC220V 0.3A | / | ||||||||||
| gG fuse protection | 16A | / | |||||||||
| Minimum switchable load | 24V 10mA | 12V 5mA | |||||||||
| Degree of protection | IP30 (terminals IP20) | IP67 (terminals IP20) | |||||||||
| Electrical life | 1,000,000 operations | 300,000 operations | |||||||||
| Mechanical life | 3,000,000 operations | 3,000,000 operations | |||||||||
| Wiring capacity | Solid conductor | 1 or 2 conductors 1…4 mm² | |||||||||
| Flexible conductor without ferrules | 1 or 2 conductors 0.75…25 mm² | ||||||||||
| Flexible conductor with ferrules | 1 or 2 conductors 0.75…25 mm² | ||||||||||
| Terminal screws | M3.5 | ||||||||||
| Tightening torque | 12N.m±0.2 | ||||||||||
Bolt installation, vertical installation of the product, ±30° between the installation.
surface and the vertical plane.
Storage ambient temperature: -40℃~+80℃. No acidic alkaline or other corrosive gas exists in the ambient air.
All the product parts and processes conform to RoHS.