Rated current In (A): 40A
Rated working voltage Ue: AC380/415/660/690V
Coil control voltage Uc (V): AC24/48/110/220/380V
Poles: 3P
Certifications: CCC, CE, TUV, CB
|
Rated working current (A) Ie |
AC-3 |
415V |
40A |
||||
|
690V |
34A |
||||||
|
AC-4 |
415V |
18.5A |
|||||
|
690V |
9A |
||||||
|
Agreed thermal current of the free air Ith/A (θ≤60℃) |
60A |
||||||
|
Rated insulating voltage Ui (V) |
690V |
||||||
|
Rated working voltage Ue (V) |
380/415V, 660/690V |
||||||
|
Power-frequency withstand voltage (V) |
1890V 1min |
||||||
|
Rated Frequency (Hz) |
50/60Hz |
||||||
|
Standards and Certificates |
·CCC,CE,TUV ·GB/T 14048.4, GB/T 14048.5, IEC60947-4-1, IEC60947-5-1 |
||||||
|
Mechanical life |
800×104 times |
||||||
|
AC-3 |
Electrical life |
80×104 times |
|||||
|
Operating frequency h−1 |
600 |
||||||
|
AC-4 |
Electrical life |
15×104 times |
|||||
|
Operating frequency h−1 |
300 |
||||||
|
AC-4(6Ie,6Ie) |
Electrical life |
15×104 times |
|||||
|
Operating frequency h−1 |
300 |
||||||
|
Rated working current (A) Ie |
380/400V |
18.5A |
|||||
|
660/690V |
9A |
||||||
|
Auxiliary contact |
Set heating current Ith A |
10A |
|||||
|
Electrical life |
AC-15(360VA) |
80×104 times |
|||||
|
DC-13(33W) |
|||||||
|
Min load connected |
17V 5mA |
||||||
|
Coil |
Rated control voltage Uc/V |
AC(50Hz,50Hz/60Hz,60Hz): 24V, 48V,110V,220V,380V |
|||||
|
Pull-in voltage range |
85%Uc ~ 110%Uc |
||||||
|
Discharge voltage range |
20%Uc ~ 75%Uc |
||||||
|
Coil power 50/60Hz VA |
Pick-up |
230VA |
|||||
|
Maintain |
32VA |
||||||
|
Contact Operation Time ms |
Closing Time (C) |
20~25ms |
|||||
|
Opening Time (O) |
8~12ms |
||||||
|
Terminal Tightening Torque N.m (max) |
Main Circuit Terminals |
2.5~5N.m |
|||||
|
Terminal Capacity (max) |
O-Type Lug Terminals |
16mm2 |
|||||
|
Protection class |
IP50 |
||||||
|
Installation Mode |
Bolt installation |
||||||
|
Working condition |
·Operation temperature:-25℃~+40℃ ·Storage Temperature: -60℃~+80℃ ·Altitude: ≤3000m. ·The relative air humidity at the installation site should not exceed 95%. Condensing should be avoided in the working environment. ·Pollution Level: 3 |
||||||


Each set of assembled product is packed in a case, which should be stored in a warehouse with the air ventilation and the temperature between -60℃ and +80℃. No acidic alkaline or other corrosive gas exists in the ambient air in the warehouse.
Quality Controls
Delivery Guarantees
Made in China
Transaction Visualization
No Worries After-sales
Professional Experience