NDC1N-185 Series AC Contactor, Nader - Image 1
NDC1N-185 Series AC Contactor, Nader - Image 2
NDC1N-185 Series AC Contactor, Nader - Thumbnail 1
NDC1N-185 Series AC Contactor, Nader - Thumbnail 2

NDC1N-185 Series AC Contactor, Nader

Rated current In (A): 185A

Rated working voltage Ue: AC380/415/660/690V

Coil control voltage Uc (V): AC/DC48~132V, AC/DC100~250V

Poles: 3P, 4P

Certifications: CCC, CE, TUV, CB

Technical parameters:

Rated working current (A) Ie

AC-3

415V

185A

690V

118A

AC-4

415V

79A

690V

69A

AC-1

690V

275A

Agreed thermal current of the free air Ith/A (θ≤60℃)

275A

Rated insulating voltage Ui (V)

1000V

Impulse withstand voltage Uimp(kV)

12kV

Rated working voltage Ue (V)

380/415V, 660/690V

Rated power/kW AC-3

220/240V

55kW

380/400V

90kW

415V

100kW

440V

100kW

500V

110kW

660/690V

110kW

Rated Frequency (Hz)

50/60Hz

Standards and Certificates

·CCC

·GB/T 14048.4, GB/T 14048.5, IEC60947-4-1, IEC60947-5-1

Mechanical life

300×104 times(≤1200times)

AC-3

Electrical life

50×104 times

Operating frequency h−1

300

AC-4

Electrical life

15×104 times

Operating frequency h−1

100

Average impedance of each pole( mΩ)

0.33mΩ

Wide voltage coil

Rated control voltage Uc/V

AC/DC: 48~132V, 100~250V

Pull-in voltage range

85%Uc min~110%Uc max

Discharge voltage range

0.48Uc min~0.52Uc min

48~132V AC/DC

Pull-in time/ms

PLC control

≤40

Power control

≤40

Discharge time/ms

PLC control

≤22

Power control

≤140

Pull-in power consumption VA/W

≤250

Retention power consumption VA/W

≤13

100~250V AC/DC

Pull-in time/ms

PLC control

≤80

Power control

≤80

Discharge time/ms

PLC control

≤30

Power control

≤140

Pull-in power consumption VA/W

≤250

Retention power consumption VA/W

≤16

Main Circuit Connection Capacity

Cable Connection

1

Size(mm²)

150mm²

Busbar Connection

2

Size(mm²)

25×3mm²

Control Circuit Connection Capacity

Flexible Wire

1wire/2wires

2.5

Solid Wire

1wire

4

Tightening Torque/N.m

0.8~1.2N.m

Protection class

IP20

Installation Mode

Bolt installation

Working condition

·Operation temperature:-25℃~+40℃

·Storage Temperature: -60℃~+80℃

·Altitude: ≤3000m.

·The relative air humidity at the installation site should not exceed 95%. Condensing should be avoided in the working environment.

·Pollution Level: 3

Outline and installation dimension

Packing and depositing:

Each set of assembled product is packed in a case, which should be stored in a warehouse with the air ventilation and the temperature between -60℃ and +80℃. No acidic alkaline or other corrosive gas exists in the ambient air in the warehouse.

Quality Controls

Delivery Guarantees

Made in China

Made in China

Transaction Visualization

No Worries After-sales

Professional Experience